The Valve Wire sealThe Valve Wire
November 27, 2026E. Nolan Beckett, MD · Editor
LIVE · 21:27 ET · NOV 27, 2026
EW ▼ MDT ▼ ABT ▲ BSX ▲
Mitral Valve (Repair & Replacement)Friday, November 27, 2026

End-Organ Dysfunction and Postprocedural Perfusion Pressure in Relation to Mortality After Mitral Transcatheter Edge-to-Edge Repair.

1 min read·By E. Nolan Beckett, MD·Source: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Key Numbers
95% confidence interval
95% CI
p < 0.001
p = 0.014
From The Valve Wire

This single-center retrospective cohort of 238 M-TEER patients combined baseline MELD-XI with perfusion pressure (PP), defined as mean arterial pressure minus central venous pressure and measured immediately after the procedure.

Over a median 730 days, 77 patients died.

Each 10 mmHg higher PP was associated with lower mortality (adjusted HR 0.684, 95% CI 0.572-0.818).

Each 1-point rise in MELD-XI was associated with higher mortality (adjusted HR 1.072).

Source Abstract

BACKGROUND: Outcomes after mitral transcatheter edge-to-edge repair (M-TEER) remain variable despite adequate mitral regurgitation reduction. Baseline end-organ dysfunction and the immediate postprocedural pressure state may capture complementary phases of risk. We assessed long-term mortality by integrating baseline MELD-XI with immediate postprocedural perfusion pressure (PP). AIMS: We aimed to assess the association of baseline MELD-XI and immediate postprocedural perfusion pressure (PP), individually and in combination, with long-term mortality after M-TEER. METHODS: This single-center retrospective study included 238 patients undergoing M-TEER. PP was calculated as mean arterial pressure (MAP) minus central venous pressure (CVP) immediately after the procedure. PP and MELD-XI were analyzed as continuous variables, with prespecified thresholds of PP 60 mmHg and MELD-XI 11 used for grouped risk stratification. RESULTS: During a median follow-up of 730 days, 77 patients died. Lower PP (adjusted hazard ratio [HR] per 10 mm Hg increase, 0.684; 95% confidence interval [CI], 0.572-0.818; p < 0.001) and higher MELD-XI (adjusted HR per 1-point increase, 1.072; 95% CI, 1.014-1.132; p = 0.014) were independently associated with mortality. Compared with high PP/low MELD-XI, risk was highest with low PP/high MELD-XI (adjusted HR, 7.80; 95% CI, 3.78-16.10; p < 0.001) and was also increased with low PP/low MELD-XI (adjusted HR, 2.84; 95% CI, 1.53-5.29; p < 0.001). PP and MAP had similar prognostic performance, whereas CVP was not independently associated with mortality. CONCLUSIONS: Integrating baseline organ status with procedure-end perfusion identified a high-risk phenotype after M-TEER. Patients with elevated MELD-XI and low PP had the poorest survival. PP did not outperform MAP, indicating a predominantly arterial-pressure signal.

Authors: Nakatsukasa T, Morikawa T, Sato T, Shigeno R, Hasegawa F et al.
Read the Original
Full article at Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Open at Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions →
The Valve Wire summarizes; we link out to primary sources for verification.