Expanding the Clinical Applications of the Closed-Loop Balloon-Stent Technique: Coronary Perforation and Saphenous Vein Graft Occlusion.

1 min read·By E. Nolan Beckett, MD·Source: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
From The Valve Wire

Two cases from a single center show a closed-loop balloon-stent construct used for targeted coronary occlusion.

In the first, an Ellis type III distal RCA perforation during PCI was sealed without a covered stent or coils.

In the second, a degenerated RCA saphenous vein graft was deliberately occluded after the native RCA chronic total occlusion was recanalized.

Both closures held on repeat angiography after wire withdrawal.

Source Abstract

Coronary vessel closure may be required in both emergent and elective settings during percutaneous coronary intervention (PCI). The closed-loop balloon-stent technique is a previously described mechanical approach to targeted vessel occlusion using routinely available catheterization laboratory equipment. We report two distinct applications of this technique. In the first case, an Ellis type III distal right coronary artery (RCA) perforation occurring during PCI was treated with the closed-loop balloon-stent system, resulting in cessation of contrast extravasation despite minimal residual distal vessel opacification. Repeat angiography after guidewire withdrawal confirmed the absence of further extravasation, and no subsequent covered stent implantation or coil embolization was required. In the second case, a severely degenerated RCA saphenous vein graft was intentionally occluded following successful recanalization of the native RCA chronic total occlusion. Repeat angiography after guidewire withdrawal confirmed persistent graft occlusion. No device loss, clinically apparent embolization, or other complications attributable to the construct were observed in either case. These cases illustrate potential applications of the technique in selected emergent and elective settings. Its use requires consideration of balloon-component non-retrievability, embolization risk, and deliverability. Further clinical experience and follow-up are required to establish its safety, appropriate indications, and long-term durability.

Authors: Ürkmez ÇA, Turgul C, Tatlı E
Read the Original
Full article at Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Open at Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions →
The Valve Wire summarizes; we link out to primary sources for verification.