Pilot study evaluating the feasibility, technical success and maturation of WavelinQ percutaneous arteriovenous fistula creation in a Southeast Asian population.
This single-center retrospective series from Singapore covers WavelinQ percutaneous arteriovenous fistula creation.
Of 62 patients mapped, 38 had suitable anatomy and 22 underwent an attempt.
Technical success was 20/22 (90.9%).
Maturation occurred in 19 of 20, but 5 required angioplasty to get there.
BACKGROUND: Percutaneous arteriovenous fistula (pAVF) creation is a minimally invasive alternative to surgical arteriovenous fistula creation for haemodialysis access. However, outcome data from Southeast Asian populations remain limited. We evaluated the feasibility, technical success, maturation, cannulation, patency and safety of WavelinQ pAVF creation during early clinical implementation at a tertiary centre in Singapore. METHODS: This single-centre retrospective observational study included patients assessed for WavelinQ pAVF creation between October 2021 and September 2023. Bilateral upper-limb duplex ultrasound vein mapping was performed to assess anatomical suitability. Patients with successful pAVF creation were followed for maturation, cannulation, reintervention, patency and complications. Patency was estimated using Kaplan-Meier analysis. RESULTS: Of 62 patients who underwent vein mapping, 38 (61.3%) were anatomically suitable, and 22 underwent attempted pAVF creation. Technical success was achieved in 20/22 patients (90.9%). Mean age was 63.1 ± 9.9 years, 63.6% were male, and 45.5% had diabetic kidney disease. Among 20 technically successful pAVFs, physiological maturation occurred in 19 (95.0%): 14 (70.0%) achieved unassisted maturation and 5 (25.0%) assisted maturation following angioplasty; one patient (5.0%) had primary failure despite endovascular salvage. Successful two-needle cannulation was achieved in 18 patients (90.0%), with a median time to first successful cannulation of 90 days (IQR 71-112). Among 16 tunnelled dialysis catheter-dependent patients, 13 (81.3%) achieved catheter-free haemodialysis. Minor complications occurred in three patients (13.6%) and resolved with manual compression. Primary patency at 3, 6, 12 and 24 months was 84%, 69%, 63% and 50%, respectively; secondary patency was 100%, 94%, 94% and 94%. CONCLUSION: WavelinQ pAVF creation was feasible and safe, with high maturation and cannulation rates. However, adjunctive maturation and maintenance interventions were frequently required, supporting structured surveillance, multidisciplinary follow-up, and dialysis-unit cannulation support.
- Surgical vs Transcatheter· JACC. Case reportsIntra-Aortic Balloon Pump Bridging to Delayed Valve Surgery After Leaflet Injury During Transcatheter Edge-to-Edge Repair.
- Surgical vs Transcatheter· Reviews in cardiovascular medicineBeyond Surgical Risk in Aortic Stenosis: The Emerging Role of Cardiac Damage Staging in Contemporary Decision-Making.
- Surgical vs Transcatheter· Journal of the Society for Cardiovascular Angiography & InterventionsScissors-Based Leaflet Modification to Prevent Coronary Obstruction in Valve-in-Valve Transcatheter Aortic Valve Replacement: The EXCALIBUR Technique-A Case Report.
- Aortic Valve (TAVR/TAVI)· Molecular genetics & genomic medicineCongenital Insensitivity to Pain With Anhidrosis Presenting as a Painful Destructive Lesion of the Proximal Tibia.
- Aortic Valve (TAVR/TAVI)· Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & InterventionsExpanding the Clinical Applications of the Closed-Loop Balloon-Stent Technique: Coronary Perforation and Saphenous Vein Graft Occlusion.
- Aortic Valve (TAVR/TAVI)· International journal of molecular medicineCDK9 regulates neointima formation following vascular injury by targeting the transcription factor Twist1.