Transcutaneous thermal gradients activate Ag

1 min read·By E. Nolan Beckett, MD·Source: Bioactive materials
From The Valve Wire

The pacemaker penalty of intra-annular self-expanding valves is real, and its cause is murky.

In the JAHA comparison (retrospective, single-center TVT registry, 2014-2024, 354 matched pairs), new pacemaker rates were 11.9% intra-annular versus 3.4% supra-annular.

Editor’s take pending for this article; this is the section commentary excerpt.
Source Abstract

Percutaneous pins make external fixation clinically versatile but create a persistent conduit for pin-site infection (PSI), biofilm formation, and infection-associated loosening. Here, near-room-temperature thermoelectric Ag2Se was integrated onto 316L Kirschner wires by Ag sputtering and room-temperature selenization. The resulting Ag2Se coating was adherent, corrosion-resistant and responsive to the body-to-ambient thermal gradient across percutaneous pins. Without external power input, this thermal gradient generated a Seebeck potential across Ag2Se-316L, accompanied by a shift in bacterial surface potential. Consistently, respiratory redox activity and intracellular adenosine triphosphate (ATP) levels decreased, together with reactive oxygen species (ROS) accumulation, membrane damage, and protein leakage. Together, these responses reduced the survival of S. aureus and E. coli and suppressed biofilm formation, while the coating retained cytocompatibility. Under mixed S. aureus/E. coli challenge, thermoelectrically activated Ag2Se-316L preserved mitochondrial homeostasis in bone marrow mesenchymal stem cells (BMSCs), accompanied by Nrf2/HO-1 upregulation and reduced DRP1Ser616 phosphorylation; it also supported osteogenic and angiogenic responses. In a rat model of infected external fixation, Ag2Se-316L pins achieved an 82.3% antibacterial rate, attenuated peri-pin inflammation, increased peri-pin bone formation and maximum pull-out force, and produced a local tissue response characterized by enhanced pro-angiogenic and osteogenic protein expression and reduced osteoclastogenic signaling. This study presents a potentially translatable coating strategy that uses the transcutaneous thermal environment to alter interfacial electrostatics, perturb bacterial bioenergetics, and preserve a regenerative peri-pin microenvironment.

Authors: Luo Y, Gao M, Wang Y, Xu K, Lu Q et al.
Read the Original
Full article at Bioactive materials
Open at Bioactive materials →
The Valve Wire summarizes; we link out to primary sources for verification.